ALL SENSORS LOGO ALL SENSORS
PHONE ALL SENSORSFAX ALL SENSORSEMAIL ALL SENSORS
  Home Products Packaging Company Team Press Engineering Resources Jobs
     
Products
 
Delicious
 
 
Cross References
 

 

APackage 0.5
 
request other information
 
databook request
½ in H2O Millivolt Output Pressure Sensor
Download datasheet (PDF)
Download dimensional drawing (PDF)

Features

  • CoBeam2™ Technology
  • 0 to 0.5” H O to 0 to 30” HO Pressure Ranges
  • Temperature Compensated
  • Calibrated Zero and Span.F
  • RoHS Compliant

Applications

  • Medical Instrumentation
  • Environmental Controls
  • HVAC

General Description

The Millivolt Output pressure sensor is based upon a proprietary technology to reduce all output offset or common mode errors.  This model provides a calibrated millivolt output with superior output offset characteristics. Output offset errors due to change in temperature, stability to warm-up, stability to long time period, and position sensitivity are all signifi cantly reduced when compared to conventional compensation methods. In addition the sensor utilizes a silicon, micromachined, stress concentration enhanced structure to provide a very linear output to measured pressure.

These calibrated and temperature compensated sensors give an accurate and stable output over a wide temperature range. This series is intended for use with non-corrosive, non-ionic working fl uids such as air, dry gases and the like.  

The output of the device is ratiometric to the supply voltage and operation from any D.C. supply voltage up to +16 V is acceptable.

Pressure Sensor Characteristics Maximum Ratings

  • Supply Voltage Vs: 16 Vdc
  • Common-mode pressure: -10 to 10 psig
  • Lead Temperature: 270°C

Environmental Specifications

Temperature Ranges

    • Compensated: 0 to 50(70)°C
    • Operating: -25 to 85°C
    • Storage: -40 to 125°C
    • Humidity Limits: 0 to 95% RH (non-condensing)

Standard Pressure Ranges

Part Number Operating Pressure Nominal Span Proof Pressure Burst Pressure
0.5 INCH-D-MV
0 - 0.5” H2O
10mV 100 In H20 200 In H20
1 INCH-D-MV 0 - 1“ H2O 10mV 100 In H20 200 In H20
2 INCH-D-MV 0 - 2“ H2O 10mv 200 In H20 200 In H20
5 INCH-D-MV 0 - 5“ H2O 20mV 200 In H2O 300 In H20
10 INCH-D-MV 0 - 10“ H2O 20mV 200 In H2O 300 In H20
20 INCH-D-MV 0 - 20“ H2O 20mV 200 In H2O 500 In H20
30 INCH-D-MV 0 - 30“ H2O 20mV 200 In H2O 800 In H20

 

Performance Characteristics for 0.5 INCH-D-MV

Parameter, note 1 Minimum Nominal Maximum Units
Operating Range, differential pressure -- ± 0.5 -- " H2O
Output Span, @ 1" H2O, note 5 ± 9.0 ± 10.0 ± 11.0 mV
Offset Voltage @ zero differential pressure -- -- ±500 uV
Offset Temperature Shift (0°C-50°C), note 2 -- -- ±250 uV
Offset Warm-up Shift, note 3 -- -- ±100 uV
Offset Position Sensitivity (±1g) -- -- ±5.0 uV
Offset Long Term Drift (one year) -- -- ±200 uV
Linearity, hysteresis error, note 4 -- 0.05 0.25 %fs
Span Shift (5°C-50°C), note 2 -- -- ±200 uV

 

Performance Characteristics for 1 INCH-D-MV

Parameter, note 1 Minimum Nominal Maximum Units
Operating Range, gage pressure -- ±1.0 -- " H2O
Output Span, @ 1" H2O, note 5 ± 9.0 ±10.0 ±11.0 mV
Offset Voltage @ zero pressure -- -- ±500 uV
Offset Temperature Shift (0°C-50°C), note 2 -- -- ±250 uV
Offset Warm-up Shift, note 3 -- -- ±100 uV
Offset Position Sensitivity (±1g) -- -- ±5.0 uV
Offset Long Term Drift (one year) -- -- ±200 uV
Linearity, hysteresis error, note 4 -- 0.05 0.25 %fs
Span Shift (5°C-50°C), note 2 -- -- ±200 uV

 

Performance Characteristics for 2 INCH-D-MV

Parameter, note 1 Minimum Nominal Maximum Units
Operating Range, differential pressure -- ±2.0 -- " H2O
Output Span, @ 1" H2O, note 5 ± 9.0 ±10.0 ±11.0 mV
Offset Voltage @ zero differential pressure -- -- ±500 uV
Offset Temperature Shift (0°C-50°C), note 2 -- -- ±250 uV
Offset Warm-up Shift, note 3 -- -- ±100 uV
Offset Position Sensitivity (±1g) -- -- ±5.0 uV
Offset Long Term Drift (one year) -- -- ±200 uV
Linearity, hysteresis error, note 4 -- 0.05 0.25 %fs
Span Shift (5°C-50°C), note 2 -- -- ±200 uV

 

Performance Characteristics for 5 INCH-D-MV

Parameter, note 1 Minimum Nominal Maximum Units
Operating Range, gage pressure -- ±5.0 -- " H2O
Output Span, @ 1" H2O, note 5 ±19.0 ±20.0 ±21.0 mV
Offset Voltage @ zero pressure -- -- ±500 uV
Offset Temperature Shift (0°C-50°C), note 2 -- -- ±150 uV
Offset Warm-up Shift, note 3 -- -- ±50 uV
Offset Position Sensitivity (±1g) -- -- ±10 uV
Offset Long Term Drift (one year) -- -- ±100 uV
Linearity, hysteresis error, note 4 -- 0.05 0.25 %fs
Span Shift (5°C-50°C), note 2 -- -- ±200 uV

 

Performance Characteristics for 10 INCH-D-MV

Parameter, note 1 Minimum Nominal Maximum Units
Operating Range, differential pressure -- ±10.0 -- " H2O
Output Span, @ 1" H2O, note 5 ±19.0 ±20.0 ±21.0 mV
Offset Voltage @ zero differential pressure -- -- ±500 uV
Offset Temperature Shift (0°C-50°C), note 2 -- -- ±150 uV
Offset Warm-up Shift, note 3 -- -- ±50 uV
Offset Position Sensitivity (±1g) -- -- ±10 uV
Offset Long Term Drift (one year) -- -- ±100 uV
Linearity, hysteresis error, note 4 -- 0.05 0.25 %fs
Span Shift (5°C-50°C), note 2 -- -- ±200 uV

 

Performance Characteristics for 20 INCH-D-MV

Parameter, note 1 Minimum Nominal Maximum Units
Operating Range, gage pressure -- ±20.0 -- " H2O
Output Span, @ 1" H2O, note 5 19.0 ±20.0 ±21.0 mV
Offset Voltage @ zero pressure -- -- ±500 uV
Offset Temperature Shift (0°C-50°C), note 2 -- -- ±150 uV
Offset Warm-up Shift, note 3 -- -- ±50 uV
Offset Position Sensitivity (±1g) -- -- ±10 uV
Offset Long Term Drift (one year) -- -- ±100 uV
Linearity, hysteresis error, note 4 -- 0.05 0.25 %fs
Span Shift (5°C-50°C), note 2 -- -- ±200 uV

 

Performance Characteristics for 30 INCH-D-MV

Parameter, note 1 Minimum Nominal Maximum Units
Operating Range, differential pressure -- ±30.0 -- " H2O
Output Span, @ 1" H2O, note 5 19.0 ±20.0 ±21.0 mV
Offset Voltage @ zero differential pressure -- -- ±500 uV
Offset Temperature Shift (0°C-50°C), note 2 -- -- ±150 uV
Offset Warm-up Shift, note 3 -- -- ±50 uV
Offset Position Sensitivity (±1g) -- -- ±10 uV
Offset Long Term Drift (one year) -- -- ±100 uV
Linearity, hysteresis error, note 4 -- 0.05 0.25 %fs
Span Shift (5°C-50°C), note 2 -- -- ±200 uV

 

Specification Notes

(1): All parameters are measured at 5.0 volt excitiation, for the nominal full scale pressure and room temperature unless otherwise specified. Pressure measurements are with positive pressure applied to port B.

(2): Shift is relative to 25°C.

(3): Shift is within the first hour of excitation applied to the device.

(4) Measured at one-half full scale rated pressure using best straight line curve fit.

(5): The voltage added to the offset voltage at full scale pressure. Nominally the output voltage range is 0.25 to 4.25 volts for minus to plus full scale pressure.

Pressure Response: for any pressure applied the response time to get to 90% of pressure applied is typically less than 500 useconds.

All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.

Download datasheet (PDF)
Download dimensional drawing (PDF)

 

 

Home | Products | Packaging | Company | Team | Press | Engineering Resources | Jobs | Links

Contact us about custom packages by phone at 408 225 4314 or by email at info@allsensors.com.