Features
- 1 to 60 inH2O Pressure Ranges
- Matched pressure port volumes
- Temperature Compensated (-25 to 85° C)
- Calibrated Zero and Span
-
Applications
- Medical Instrumentation
- Environmental Controls
- HVAC
equivalent Circuit

Pressure Sensor Maximum Ratings
Environmental Specification
Help Me Choose
Choose A Part Number Below To View Performance Characteristics
Pressure Range | Differential | Absolute | Gauge |
1 INCH-D2-P4V-MINI Performance Characteristics
ClosePARAMETER | MIN | NOM | MAX | UNITS | Notes |
Operating Range, differential pressure | -- | ±1.0 | -- | inH2O | - |
Output Span | ±1.90 | ±2.0 | ±2.10 | volt | 5 |
Offset Voltage @ zero differential pressure | 2.15 | 2.25 | 2.35 | volt | - |
Offset Temperature Shift (-25°C-85°C) | -- | -- | ±60 | mvolt | 2 |
Offset Warm-up Shift | -- | ±10 | -- | mvolt | 3 |
Offset Position Sensitivity (±1g) | -- | ±5 | -- | mvolt | - |
Offset Long Term Drift (one year) | -- | ±10 | -- | mvolt | - |
Linearity, hysteresis error | -- | 0.05 | 0.25 | %fs | 4 |
Span Shift (-25°C-85°C) | -- | -- | ±2 | %span | 2 |
Standard Pressure Range
Operating Pressure
±1 inH2O
Nominal Span
4 V
Proof Pressure
100 inH2O
Burst Pressure
200 inH2O