ACPC Series H-Grade Pressure Sensors
-
Features
- 4 inH2O to 100 PSI Pressure Ranges
- 0.5 % linearity...high accuracy version
- Temperature Compensated
- Calibrated Zero and Span
-
Applications
- Medical Instrumentation
- Environmental Controls
- HVAC
equivalent Circuit

Pressure Sensor Maximum Ratings
Environmental Specification
Help Me Choose
Choose A Part Number Below To View Performance Characteristics
Pressure Range | Differential | Absolute | Gauge |
4 inH2O | 4 INCH-D-HGRADE-MINI | -- | 4 INCH-G-HGRADE-MINI 4 INCH-GF-HGRADE-MINI |
0.3 PSI | 0.3 PSI-D-HGRADE-MINI | -- | 0.3 PSI-G-HGRADE-MINI 0.3 PSI-GF-HGRADE-MINI |
10 inH2O | 10 INCH-D-HGRADE-MINI | -- | 10 INCH-G-HGRADE-MINI 10 INCH-GF-HGRADE-MINI |
1 PSI | 1 PSI-D-HGRADE-MINI | -- | 1 PSI-G-HGRADE-MINI 1 PSI-GF-HGRADE-MINI |
5 PSI | 5 PSI-D-HGRADE-MINI | -- | 5 PSI-G-HGRADE-MINI 5 PSI-GF-HGRADE-MINI |
15 PSI | 15 PSI-D-HGRADE-MINI | 15 PSI-A-HGRADE-MINI 15 PSI-AF-HGRADE-MINI | 15 PSI-G-HGRADE-MINI 15 PSI-GF-HGRADE-MINI |
30 PSI | 30 PSI-D-HGRADE-MINI | 30 PSI-A-HGRADE-MINI 30 PSI-AF-HGRADE-MINI | 30 PSI-G-HGRADE-MINI 30 PSI-GF-HGRADE-MINI |
100 PSI | -- | -- | 100 PSI-G-HGRADE-MINI 100 PSI-GF-HGRADE-MINI |
15 PSI-GF-HGRADE-MINI Performance Characteristics
ClosePARAMETER | MIN | NOM | MAX | UNITS | Notes |
Operating Range, gage pressure | - | 15.0 | - | PSIG | - |
Output Span | 89.1 | 90.0 | 90.9 | mV | 5 |
Offset Voltage @ zero gage pressure | - | - | ±0.5 | mV | - |
Offset Temperature Shift (0°C-70°C) | - | - | ±0.5 | mV | 2 |
Linearity, hysteresis error | - | 0.25 | 0.5 | %fs | 4 |
Span Shift (0°C-70°C) | - | - | ±1 | %fs | 2 |
Standard Pressure Range
Operating Pressure
0-15 PSIG
Specification notes
NOTE 1: ALL PARAMETERS ARE MEASURED AT 12.0 VOLT EXCITATION, FOR THE NOMINAL FULL SCALE PRESSURE AND ROOM TEMPERATURE UNLESS OTHERWISE SPECIFIED. PRESSURE MEASUREMENTS ARE WITH POSITIVE PRESSURE APPLIED TO PORT B.
NOTE 2: SHIFT IS RELATIVE TO 25°C.
NOTE 3: SHIFT IS WITHIN THE FIRST HOUR OF EXCITATION APPLIED TO THE DEVICE.
NOTE 4: MEASURED AT ONE-HALF FULL SCALE RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT.
NOTE 5: THE VOLTAGE ADDED TO THE OFFSET VOLTAGE AT FULL SCALE PRESSURE.