AXCX Series C-Grade
-
Features
- 4 inH2O to 100 PSI Pressure Ranges
- 1 % Linearity Version
- Temperature Compensated
- Calibrated Zero and Span
-
Applications
- Medical Instrumentation
- Environmental Controls
- HVAC
equivalent Circuit

Pressure Sensor Maximum Ratings
Environmental Specification
Help Me Choose
Choose A Part Number Below To View Performance Characteristics
Pressure Range | Differential | Absolute | Gauge |
4 inH2O | 4 INCH-D-CGRADE-MV | -- | -- |
0.3 PSI | 0.3 PSI-D-CGRADE-MV | -- | -- |
1 PSI | 1 PSI-D-CGRADE-MV | -- | -- |
5 PSI | 5 PSI-D-CGRADE-MV | -- | -- |
15 PSI | 15 PSI-D-CGRADE-MV | 15 PSI-A-CGRADE-MV | -- |
30 PSI | 30 PSI-D-CGRADE-MV | -- | -- |
100 PSI | 100 PSI-D-CGRADE-MV | -- | -- |
150 PSI | 150 PSI-D-CGRADE-MV | -- | -- |
150 PSI-D-CGRADE-MV Performance Characteristics
ClosePARAMETER | MIN | NOM | MAX | UNITS | Notes |
Operating Range, differential pressure | -- | 150.0 | -- | PSI | - |
Output Span | 86 | 90 | 95 | mV | 5 |
Offset Voltage @ zero differential pressure | -- | -- | ±1 | mV | - |
Offset Temperature Shift (0°C-70°C) | -- | -- | ±1 | mV | 2 |
Linearity, hysteresis error | -- | 0.5 | 1.0 | %fs | 4 |
Span Shift (0°C-70°C) | -- | -- | ±2 | %fs | 2 |
Standard Pressure Range
Operating Pressure
0 - 150 PSI
Nominal Span
90 mV
Proof Pressure
200 PSI
Burst Pressure
250 PSI
Specification notes
Specification Notes
NOTE 1: ALL PARAMETERS ARE MEASURED AT 12.0 VOLT EXCITATION, FOR THE NOMINAL FULL SCALE PRESSURE AND ROOM TEMPERATURE UNLESS
OTHERWISE SPECIFIED. PRESSURE MEASUREMENTS ARE WITH POSITIVE PRESSURE APPLIED TO PORT B.
NOTE 2: SHIFT IS RELATIVE TO 25°C.
NOTE 3: SHIFT IS WITHIN THE FIRST HOUR OF EXCITATION APPLIED TO THE DEVICE.
NOTE 4: MEASURED AT ONE-HALF FULL SCALE RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT.
NOTE 5: THE VOLTAGE ADDED TO THE OFFSET VOLTAGE AT FULL SCALE PRESSURE.