Miniature Low Pressure Sensors
20 INCH-D2DIP-MV-SDXL
Performance Characteristics for 20 INCH-D2DIP-MV-SDXL
Parameter, note 1
Minimum
Nominal
Maximum
Units
Operating Range, differential pressure
5.0
“H2O
Output Span, note 5
19.0
20.0
21.0
mV
Offset Voltage @ zero differential pressure
±500
uV
Offset Temperature Shift (0°C-70°C), note 2
±150
uV
Offset Warm-up Shift, note 3
±50
uV
Offset Position Sensitivity (1g)
±5
uV
Offset Long Term Drift (one year)
±100
uV
Linearity, hysteresis error, note 4
0.05
0.25
Span Shift (0°C-70°C), note 2
±200
uV
Standard Pressure Ranges for 20 INCH-D2DIP-MV-SDXL
Operating Pressure
0 - 20 “H2O
Specification Notes
NOTE 1: ALL PARAMETERS ARE MEASURED AT 12.0 VOLT EXCITATION, FOR THE NOMINAL FULL SCALE PRESSURE AND ROOM TEMPERATURE UNLESS OTHERWISE SPECIFIED. PRESSURE MEASUREMENTS ARE WITH POSITIVE PRESSURE APPLIED TO THE B-PORT CONFIGURATION.
NOTE 2: SHIFT IS RELATIVE TO 25°C.
NOTE 3: SHIFT IS WITHIN THE FIRST HOUR OF EXCITATION APPLIED TO THE DEVICE.
NOTE 4: MEASURED AT ONE-HALF FULL SCALE RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT.
NOTE 5: THE VOLTAGE ADDED TO THE OFFSET VOLTAGE AT FULL SCALE PRESSURE.
LinkedIn