MAMP Series Prime Grade
-
Features
- 1 to 60 inH2O Pressure Ranges
- Matched pressure port volumes
- Temperature Compensated (-25 to 85°C)
- Calibrated Zero and Span
-
Applications
- Medical Instrumentation
- Environmental Controls
- HVAC
equivalent Circuit

Pressure Sensor Maximum Ratings
Environmental Specification
Help Me Choose
Choose A Part Number Below To View Performance Characteristics
Pressure Range | Differential | Absolute | Gauge |
1 inH2O | 1 INCH-D1-P4V-MINI 1 INCH-D2-P4V-MINI | -- | 1 INCH-G-P4V-MINI |
5 inH2O | 5 INCH-D1-P4V-MINI 5 INCH-D2-P4V-MINI | -- | 5 INCH-G-P4V-MINI |
10 inH2O | 10 INCH-D1-P4V-MINI 10 INCH-D2-P4V-MINI | -- | 10 INCH-G-P4V-MINI |
20 inH2O | 20 INCH-D1-P4V-MINI 20 INCH-D2-P4V-MINI | -- | 20 INCH-G-P4V-MINI |
30 inH2O | 30 INCH-D1-P4V-MINI 30 INCH-D2-P4V-MINI | -- | 30 INCH-G-P4V-MINI |
60 inH2O | 60 INCH-D1-P4V-MINI 60 INCH-D2-P4V-MINI | -- | -- |
60 INCH-D2-P4V-MINI Performance Characteristics
ClosePARAMETER | MIN | NOM | MAX | UNITS | Notes |
Operating Range, differential pressure | -- | ±60.0 | -- | inH2O | - |
Output Span | ±1.90 | ±2.0 | ±2.10 | volt | 5 |
Offset Voltage @ zero differential pressure | 2.15 | 2.25 | 2.35 | volt | - |
Offset Temperature Shift (-25°C-85°C) | -- | -- | ±20 | mvolt | 2 |
Offset Warm-up Shift | -- | ±5 | -- | mvolt | 3 |
Offset Position Sensitivity (±1g) | -- | ±5 | -- | mvolt | - |
Offset Long Term Drift (one year) | -- | ±5 | -- | mvolt | - |
Linearity, hysteresis error | -- | 0.05 | 0.25 | %fs | 4 |
Span Shift (-25°C-85°C) | -- | -- | ±1 | %span | 2 |
Standard Pressure Range
Operating Pressure
±60 inH2O
Nominal Span
4V
Proof Pressure
500 inH2O
Burst Pressure
800 inH2O
Specification notes
NOTE 1: ALL PARAMETERS ARE MEASURED AT 5.0 VOLT EXCITATION, FOR THE NOMINAL FULL SCALE PRESSURE AND ROOM TEMPERATURE UNLESS OTHERWISE SPECIFIED. PRESSURE MEASUREMENTS ARE WITH POSITIVE PRESSURE APPLIED TO THE FRONT PORT.
NOTE 2: SHIFT IS RELATIVE TO 25°C.
NOTE 3: SHIFT IS WITHIN THE FIRST HOUR OF EXCITATION APPLIED TO THE DEVICE.
NOTE 4: MEASURED AT ONE-HALF FULL SCALE RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT.
NOTE 5: THE VOLTAGE ADDED TO THE OFFSET VOLTAGE AT FULL SCALE PRESSURE. NOMINALLY THE OUTPUT VOLTAGE RANGE IS 0.25 TO 4.25 VOLTS FOR MINUS TO PLUS FULL SCALE PRESSURE.