BLVR Series
-
Features
- 1 to 30 inH2O
- 1.8V to 3.3V Supply Voltage
- 0.3% Linearity
- Offset Compensated
- Superior Position Sensitivity
- Improved Warm-Up Shift Distribution
- Parylene Coating Available Upon Request
-
Applications
- Medical Instrumentation
- Environmental Controls
- HVAC
- Portable / Hand Held Devices
equivalent Circuit

Pressure Sensor Maximum Ratings
Environmental Specification
BLVR-L01D Performance Characteristics
ClosePARAMETER | MIN | NOM | MAX | UNITS | Notes |
Output Span | 4.5 | 8.0 | 11.5 | mV | 4 |
Offset Voltage @ Zero Diff. Pressure | - | - | ±8.0 | mV | - |
Offset Temperature Shift (0°C-70°C) | - | ±0.1 | - | mV | 1 |
Offset Warm-up Shift | - | ±10 | ±80 | uV | 2 |
Offset Position Sensitivity (1g) | - | ±0.2 | - | uV | - |
Offset Long Term Drift (One Year) | - | ±80 | - | uV | - |
Linearity, Hysteresis Error | - | 0.1 | ±0.3 | %FSS | 3 |
Response Time (10% to 90% Pressure Response) | - | 100 | - | uS | - |
Front to Back Linearity | - | 0.25 | - | %FSS | 5 |
Temperature Effect on Resistance (0°C-70°C) | - | 2800 | - | ppm/°C | - |
Temperature Effect on Span (0°C-70°C) | - | -1900 | - | ppm/°C | - |
Input Resistance | - | 1.5 | - | k ohm | - |
Output Resistance | - | 1.5 | - | k ohm | - |
Standard Pressure Range
Operating Range
±1 inH2O
Proof Pressure
100 inH2O
Burst Pressure
300 inH2O
-
-
Specification notes
NOTE 1: SHIFT IS RELATIVE TO 25°C.
NOTE 2: SHIFT IS WITHIN THE FIRST HOUR OF EXCITATION APPLIED TO THE DEVICE.
NOTE 3: MEASURED AT ONE-HALF FULL SCALE RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT.
NOTE 4: THE SPAN IS THE ALGEBRAIC DIFFERENCE BETWEEN FULL SCALE OUTPUT VOLTAGE AND THE OFFSET VOLTAGE.