The BDS Basic Pressure Sensor was designed with the idea of combining two sensing elements into one package. This sensor is designed to provide a precise fl ow measurement by combining a differential and absolute sensing element in the same package. By combining the differential and absolute sensing element, engineers can save cost and space in today’s smaller devices.   The BASIC series pressure sensors are based upon a proprietary technology to reduce the size of the sensor and yet maintain a high level of performance. Output offset errors due to position sensitivity; packaging stress and long term drift are all signifi cantly reduced when compared to conventional silicon sensors. In addition, the sensor utilizes a silicon, micromachined, stress concentration enhanced structure to provide a very linear output to measured pressure.   This series is intended for use with non-corrosive, non-ionic working fl uids such as air, dry gases and the like. The output of the device is ratiometric to the supply voltage.
  • Features

    • Dual Sensing Elements (Absolute & Differential)
    • li>Top constraint absolute sensing element for helium applications li>Parylene coating available upon request li>RoHS Compliant
  • Applications

    • Gas Flow Measurement

equivalent Circuit

Pressure Sensor Maximum Ratings

Supply Voltage VS

6 Vdc

Lead Temperature (soldering 2-4 sec.)

270°C

Environmental Specification

Operating

-25 to 85°C

Storage

-40 to 125°C

Humidity Limits

0 to 95% RH (non condensing)

Available Package

Click On Package Image Below To View Package Drawing

Help Me Choose

Choose A Part Number Below To View Performance Characteristics

Pressure Range Differential Absolute Gauge
10 inH2O BDS-L10D-030A-N9 -- --
30 PSI -- BDS-L10D-030A-N9 --
10 inH2O BDS-L10D-100A-N9 -- --
100 PSI -- BDS-L10D-100A-N9 --
 

BDS-L10D-100A-N9 Performance Characteristics

Close
PARAMETER MIN NOM MAX UNITS Notes
Offset Voltage (@1 atm) -20.0 -- +120 mv -
Temperature Effect on Offset -- ±3.0 -- uV/V/°C 2
Temperature Effect on Resistance 1200 2600 3100 ppm/°C 2,5
Temperature Effect on Span -1500 -1900 -2400 ppm/°C 2,5
Linearity error -- ±0.2 ±0.5 % FSS 4,5
Hysteresis error -- ±0.01 -- % FSS -
Input Resistance 2.0 2.5 3.0 kohms -
Output Resistance -- 0.1 -- % FSS -

Standard Pressure Range

Operating Pressure

0 - 100 PSIA

0 - 10 inH2O

Nominal

3.0

3.0

Std Dev.

±0.28

±0.40

Units

mV/PSI

mV/inH2O

Proof Pressure

150 PSI

15 PSI

Burst Pressure

150 PSI

30 PSI

Specification notes

NOTE 1: ALL PARAMETERS ARE MEASURED AT 5.0 VOLT EXCITATION, FOR THE NOMINAL FULL SCALE PRESSURE AND ROOM TEMPERATURE
UNLESS OTHERWISE SPECIFIED. PRESSURE MEASUREMENTS ARE WITH POSITIVE PRESSURE TO PORT B.

NOTE 2: SHIFT IS RELATIVE TO 25°C.

NOTE 3: SHIFT IS WITHIN THE FIRST YEAR OF OPERATION.

NOTE 4: MEASURED AT ONE-HALF FULL SCALE RATED PRESSURE USING BEST STRAIGHT LINE CURVE FIT.

NOTE 5: PARAMETER IS CHARACTERIZED AND NOT 100% TESTED. MINIMUM AND MAXIMUM VALUES INDICATED AS A DESIGN REFERENCE.

Standard Package