CPA 602 Series
-
Features
- 30 to 6000 PSI
- Easy mounting
- Vacuum resistant
- Supply voltage 4.5 to 5.5 VDC
- Ratiometric
- Total error better than 0.4% FS
-
Applications
- Medical Devices
- Environmental Controls
- Plant and Mechanical Engineering
- Automotive
equivalent Circuit
Pressure Sensor Maximum Ratings
Environmental Specification
Help Me Choose
Choose A Part Number Below To View Performance Characteristics
Pressure Range | Differential | Absolute | Gauge |
30 PSI | -- | -- | CPA602G-030301001 |
-- | -- | CPA602G-030999001 | |
75 PSI | -- | -- | CPA602G-075301001 |
-- | -- | CPA602G-075999001 | |
150 PSI | -- | -- | CPA602G-150301001 |
-- | -- | CPA602G-150999001 | |
300 PSI | -- | -- | CPA602G-300301001 |
-- | -- | CPA602G-300999001 | |
750 PSI | -- | -- | CPA602G-750301001 |
-- | -- | CPA602G-750999001 | |
1000 PSI | -- | -- | CPA602G-1K5301001 |
-- | -- | CPA602G-1K5999001 | |
3000 PSI | -- | -- | CPA602G-3K0301001 |
-- | -- | CPA602G-3K0999001 | |
6000 PSI | -- | -- | CPA602G-6K0301001 |
-- | -- | CPA602G-6K0999001 |
CPA602G-075999001 Performance Characteristics
CloseReference Conditions | - | - | - | - | - |
Supply Voltage | 4.5 to 5.5 VDC | - | - | - | - |
Output Signal / Supply | 3-wire ratiometric: 10 to 90% of V S (V0 = 0.5 to 4.5 V DC @VS = 5.0 V) | - | - | - | - |
Reference temperature | 25 °C | - | - | - | - |
Measuring supply voltage | 5 VDC | - | - | - | - |
Performance Characteristics | - | - | - | - | - |
Supply Current | ≤ 2.5 mA | - | - | - | - |
Offset | 0.5 V @ VS = 5 V | - | - | - | - |
Span | 4.0 V @ VS = 5 V | - | - | - | - |
Output Load Resistance | ≥ 5 kΩ | - | - | - | - |
Total Error | Pressure ranges: ≤ 750 psi: ≤ ± 0.4% FS (terminal based) Pressure ranges: > 750 psi: ≤ ± 0.8% FS typs. (1.5% FS max.) (terminal based) (redu | - | - | - | - |
Calibration Error | ≤ ± 0.3 % FS | - | - | - | - |
Long term stability | ≤ ± 0.3 % FS / year (at reference conditions) | - | - | - | - |
TC Offset (TC0) | ≤ ± 0.02 % FS / °C 2 | - | - | - | - |
TC Span (TCS) | ≤ - 0.012 % FS / °C 2 | - | - | - | - |
Standard Pressure Range
Operating Range
0 - 75 PSI
Proof Pressure
150 PSI
Burst Pressure
300 PSI
Output Signal
0.5 to 4.5 mV/V