ELVA Series
-
Features
- 100 mbar to 10 bar
- Analog Output
- 3V or 5V Supply Voltage Options
- All Sensors' Superior, Dual-Die CoBeam2 TM Technology
- Various Lead and Port Options Available
-
Applications
- Medical Devices
- Medical Instrumentation
- Respiratory
- Portable / Hand-Held Equipment
- Environmental Controls
- Environmental Instrumentation
- Environmental Monitoring
- HVAC
- Industrial Controls
- Altimeters
- Chemical Analysis
- Meteorology
equivalent Circuit

Pressure Sensor Maximum Ratings
Environmental Specification
Help Me Choose
Choose A Part Number Below To View Performance Characteristics
Pressure Range | Differential | Absolute | Gauge |
1 psi | ELVA-001D | -- | ELVA-001G |
100 mbar | ELVA-M100D | -- | ELVA-M100G |
250 mbar | ELVA-M250D | -- | ELVA-M250G |
500 mbar | ELVA-M500D | -- | ELVA-M500G |
1 bar | ELVA-B001D | ELVA-B001A | ELVA-B001G |
2 bar | -- | ELVA-B002A | -- |
2.5 bar | -- | -- | ELVA-BF25G |
5 bar | -- | -- | ELVA-B005G |
100 psi | -- | -- | ELVA-100G |
10 bar | -- | -- | ELVA-B010G |
ELVA-M250G Performance Characteristics
ClosePARAMETER | MIN | NOM | MAX | UNITS | Notes |
Full Scale Span (FSS) | - | - | - | - | - |
- 3V Supply Option | - | 2.4 | - | V | 5 |
- 5V Supply Option | - | 4 | - | V | 5 |
Full Scale Output (FSO) (3V Option) | - | - | - | - | - |
- Min Pressure | 0.26 | 0.3 | 0.34 | V | - |
- Max Pressure | 2.66 | 2.7 | 2.74 | V | - |
Full Scale Output (FSO) (5V Option) | - | - | - | - | - |
- Min Pressure | 0.44 | 0.5 | 0.56 | V | - |
- Max Pressure | 4.44 | 4.5 | 4.56 | V | - |
Offset (3V Option) | 0.26 | 0.3 | 0.34 | V | - |
Offset (5V Option) | 0.44 | 0.5 | 0.56 | V | - |
Accuracy | - | - | ±0.25 | %FSS | 6 |
Total Error Band (TEB) | - | - | ±1.5 | %FSS | 7 |
A/D Resolution | - | 12 | - | bit | - |
D/A Resolution | - | - | 11 | bit | - |
Response Delay | - | 0.5 | - | ms | 9 |
Current Consumption | - | - | - | - | - |
- 3V Supply Option | - | 4.5 | - | mA | - |
- 5V Supply Option | - | 5.3 | - | mA | - |
Standard Pressure Range
Operating Range
0 to 250 mbar
Proof Pressure
1034 mbar
Burst Pressure
5171 mbar
Common Mode Pressure
17237 mbar
Specification notes
NOTE 1: Pressure ranges in Pa and kPa are expressed as an approximate value.
NOTE 2: Differential Proof Pressure: The maximum pressure which may safely be applied to one port of the product for it to remain in specification once pressure is returned to the operating pressure range. Exposure to higher pressures may cause permanent damage to the product.
NOTE 3: Differential Burst Pressure: The maximum pressure that may be applied to one port of the product without causing escape of pressure media. Product should not be expected to function after exposure to any pressure beyond the burst pressure.
NOTE 4: Common Mode Pressure: The maximum pressure that can be applied simultaneously to both ports of a differential pressure sensor without causing escape of pressure media. Product should not be expected to function after exposure to any pressure beyond this maximum pressure.
NOTE 5: Full Scale Span (FSS) is the algebraic difference between the output signal for the highest and lowest specified pressure.
NOTE 6: Accuracy is the measured deviation based on Best Fit Straight Line (BFSL).
NOTE 7: Total Error Band is calculated from a combination of all possible errors, including offset, span temperature, calibration, linearity, pressure hysteresis, offset warm-up shift, offset position sensitivity, and long term offset drift.
NOTE 8: Parameter is characterized and not 100% tested.
NOTE 9: Max. delay time between pressure change at the pressure die and signal change at the output.