ELVH Series
-
Features
- 0.5 up to 30 inH2O and 1 up to 150 psi and 100 mbar up to 10 bar
- Digital I2C or SPI in 14 Bit Output with Analog Option
- 3.3V or 5V Supply Voltage Options
- All Sensors' Superior, Dual-Die CoBeam2 TM Technology
- Various Lead and Port Options Available
-
Applications
- Medical Devices
- Medical Instrumentation
- Respiratory
- Portable / Hand-Held Equipment
- Environmental Controls
- Environmental Instrumentation
- Environmental Monitoring
- HVAC
- Industrial Controls
- Altimeters
- Chemical Analysis
- Meteorology
equivalent Circuit

Pressure Sensor Maximum Ratings
Environmental Specification
Help Me Choose
Choose A Part Number Below To View Performance Characteristics
ELVH-L30G Performance Characteristics
ClosePARAMETER | MIN | NOM | MAX | UNITS | Notes |
Full Scale Span (FSS) | - | - | - | - | - |
- 10% - 90%, 5% - 85% Transfer Function Options | - | 13107 | - | Count (Dec) | 5 |
- 5% - 95%, 4% - 84% Transfer Function Options | - | 14746 | - | Count (Dec) | 5 |
Offset | - | - | - | - | - |
- 10% - 90% Transfer Function Option | - | 1638 | - | Count (Dec) | - |
- 5% - 95% Transfer Function Option | - | 819 | - | Count (Dec) | - |
- 5% - 85% Transfer Function Option | - | 819 | - | Count (Dec) | - |
- 4% - 94% Transfer Function Option | - | 655 | - | Count (Dec) | - |
Accuracy | - | - | ±0.25 | %FSS | 6 |
Total Error Band (TEB) | - | ±0.5 | ±1 | %FSS | 7 |
Position Sensitivity | - | ±0.1 | - | %FSS | 8 |
Startup Time | - | - | 3 | ms | - |
Response Time | - | 0.46 | - | ms | - |
Supply Current | - | - | - | - | - |
- 3.3V Supply Option | - | 3.1 | 3.9 | mA | - |
- 5V Supply Option | - | 3.7 | 4.6 | mA | - |
Standard Pressure Range
Operating Range
0 to 30 inH2O
Proof Pressure
350 inH2O
Burst Pressure
415 inH2O
Common Mode Pressure
415 inH2O
Specification notes
NOTE 1: Pressure ranges in Pa and kPa are expressed as an approximate value.
NOTE 2: Differential Proof Pressure: The maximum pressure which may safely be applied to one port of the product for it to remain in specification once pressure is returned to the operating pressure range. Exposure to higher pressures may cause permanent damage to the product.
NOTE 3: Differential Burst Pressure: The maximum pressure that may be applied to one port of the product without causing escape of pressure media. Product should not be expected to function after exposure to any pressure beyond the burst pressure.
NOTE 4: Common Mode Pressure: The maximum pressure that can be applied simultaneously to both ports of a differential pressure sensor without causing escape of pressure media. Product should not be expected to function after exposure to any pressure beyond this maximum pressure.
NOTE 5: Full Scale Span (FSS) is the algebraic difference between the output signal for the highest and lowest specified pressure.
NOTE 6: Accuracy is the measured deviation based on Best Fit Straight Line (BFSL).
NOTE 7: Total Error Band is calculated from a combination of all possible errors, including offset, span temperature, calibration, linearity, pressure hysteresis, offset warm-up shift, offset position sensitivity, and long term offset drift.
NOTE 8: Parameter is characterized and not 100% tested.
NOTE 9: Max. delay time between pressure change at the pressure die and signal change at the output.