MLDX Series

The MLDX series sensors are based on All Sensors’ CoBeam2 TM Technology. This reduces package stress susceptibility, resulting in improved overall long term stability.

 

These calibrated and compensated sensors give an accurate and stable output over a wide temperature range. This series is intended for use with non-corrosive, non-ionic working fluids such as air or dry gases.

 

A protective parylene coating is optionally available for moisture/harsh media protection.

 

Devices are available in 5 and 10 inH2O and 1, 5, 15, 30, and 100 PSI pressure ranges.

  • Features

    • 5 inH2O to 100 PSI  Pressure Ranges
    • Matched pressure port volumes
    • Temperature Compensated
    • Calibrated Zero and Span
  • Applications

    • HVAC
    • Industrial Controls
    • Environmental Controls
    • Air Sampling Equipment
    • Portable / Handheld Equipment

equivalent Circuit

Pressure Sensor Maximum Ratings

Supply Voltage, Vs

20 Vdc

Lead Temperature (soldering 2-4 sec.)

270°C

Environmental Specification

Compensated

0 to 50°C

Operating

-40 to 85°C

Storage

-40 to 125°C

Humidity Limits (non condensing)

0 to 95% RH

Available Package

Click On Package Image Below To View Package Drawing

Help Me Choose

Choose A Part Number Below To View Performance Characteristics

Pressure Range Differential Absolute Gauge
5 inH2O MLDX-L05D -- --
10 inH2O MLDX-L10D -- --
1 PSI MLDX-001D -- --
5 PSI MLDX-005D -- --
15 PSI MLDX-015D MLDX-015A --
30 PSI MLDX-030D MLDX-030A --
100 PSI MLDX-100D MLDX-100A --
 

MLDX-001D Performance Characteristics

Close
PARAMETER MIN NOM MAX UNITS Notes
Full-Scale Span (FSS) 14 15 16 mV 1
Span Temperature Effect (0°C to 50°C) - - ±1.5 %FSS 2
Offset Voltage at Zero Diff. Pressure - - ±500 uV -
Offset Temperature Effect (0°C to 50°C) - - ±250 uV 2
Offset Long-Term Drift (One Year) ' ±150 - uV -
Combined Linearity and Hysteresis Error - 0.2 ±0.3 %FSS 3
Response Time - 500 - us 4
Common Mode Voltage 2 2.5 3 V 5
Input Resistance - 27 - kOhm 6
Output Resistance - 3.2 - kOhm 7

Standard Pressure Range

Operating Range

±1 PSI

Proof Pressure

7 PSI

Burst Pressure

10 PSI

Nominal Span

15 mV

Specification notes

NOTE 1: FULL-SCALE SPAN IS THE ALGEBRAIC DIFFERENCE BETWEEN THE OUTPUT VOLTAGE AT FULL-SCALE AND ZERO PRESSURE

NOTE 2: OFFSET AND SPAN ERRORS RELATIVE TO THE 25°C [77°F] READING

NOTE 3: MEASURED AT ONE-HALF FULL-SCALE PRESSURE USING BFSL

NOTE 4: RESPONSE TIME FOR A ZERO TO FULL-SCALE PRESSURE STEP CHANGE, 10% TO 90% RISE TIME

NOTE 5: COMMON MODE VOLTAGE IS THE AVERAGE OF THE OUTPUT ARMS FOR VS = 10VDC

NOTE 6: INPUT RESISTANCE IS THE RESISTANCE BETWEEN VS AND GROUND

NOTE 7: OUTPUT RESISTANCE IS THE RESISTIANCE BETWEEN OUPUT+ AND OUTPUT-