MLDX Series
-
Features
- 5 inH2O to 100 PSI Pressure Ranges
- Matched pressure port volumes
- Temperature Compensated
- Calibrated Zero and Span
-
Applications
- HVAC
- Industrial Controls
- Environmental Controls
- Air Sampling Equipment
- Portable / Handheld Equipment
equivalent Circuit

Pressure Sensor Maximum Ratings
Environmental Specification
Help Me Choose
Choose A Part Number Below To View Performance Characteristics
MLDX-L10D Performance Characteristics
ClosePARAMETER | MIN | NOM | MAX | UNITS | Notes |
Full-Scale Span (FSS) | 16 | 17 | 18 | mV | 1 |
Span Temperature Effect (0°C to 50°C) | - | - | ±1.5 | %FSS | 2 |
Offset Voltage at Zero Diff. Pressure | - | - | ±500 | uV | - |
Offset Temperature Effect (0°C to 50°C) | - | - | ±250 | uV | 2 |
Offset Long-Term Drift (One Year) | ' | ±150 | - | uV | - |
Combined Linearity and Hysteresis Error | - | 0.2 | ±0.3 | %FSS | 3 |
Response Time | - | 500 | - | us | 4 |
Common Mode Voltage | 2 | 2.5 | 3 | V | 5 |
Input Resistance | - | 27 | - | kOhm | 6 |
Output Resistance | - | 3.2 | - | kOhm | 7 |
Standard Pressure Range
Operating Range
±10 inH2O
Proof Pressure
200 inH2O
Burst Pressure
300 inH2O
Nominal Span
17 mV
Specification notes
NOTE 1: FULL-SCALE SPAN IS THE ALGEBRAIC DIFFERENCE BETWEEN THE OUTPUT VOLTAGE AT FULL-SCALE AND ZERO PRESSURE
NOTE 2: OFFSET AND SPAN ERRORS RELATIVE TO THE 25°C [77°F] READING
NOTE 3: MEASURED AT ONE-HALF FULL-SCALE PRESSURE USING BFSL
NOTE 4: RESPONSE TIME FOR A ZERO TO FULL-SCALE PRESSURE STEP CHANGE, 10% TO 90% RISE TIME
NOTE 5: COMMON MODE VOLTAGE IS THE AVERAGE OF THE OUTPUT ARMS FOR VS = 10VDC
NOTE 6: INPUT RESISTANCE IS THE RESISTANCE BETWEEN VS AND GROUND
NOTE 7: OUTPUT RESISTANCE IS THE RESISTIANCE BETWEEN OUPUT+ AND OUTPUT-