SPM 402 Series
-
Features
- 5 to 500 PSI
- -40 to 125°C Temperature Range
- Calibrated and compensated output
- Supply voltage 10V
- High accuracy (max 0.25% linearity and max 0.05% hysteresis)
-
Applications
- Medical Devices
- HVAC Controls
- Laboratory & Calibration Applications
- Hydraulic Biomedical Instruments
equivalent Circuit

Pressure Sensor Maximum Ratings
Environmental Specification
Help Me Choose
Choose A Part Number Below To View Performance Characteristics
Pressure Range | Differential | Absolute | Gauge |
5 PSI | -- | -- | SPM402G-P005xxxxxxxxxxxx |
15 PSI | -- | SPM402A-P015xxxxxxxxxxxx | SPM402G-P015xxxxxxxxxxxx |
30 PSI | -- | SPM402A-P030xxxxxxxxxxxx | SPM402G-P030xxxxxxxxxxxx |
50 PSI | -- | SPM402A-P050xxxxxxxxxxxx | SPM402G-P050xxxxxxxxxxxx |
100 PSI | -- | SPM402A-P100xxxxxxxxxxxx | SPM402G-P100xxxxxxxxxxxx |
300 PSI | -- | SPM402A-P300xxxxxxxxxxxx | SPM402G-P300xxxxxxxxxxxx |
500 PSI | -- | SPM402A-P500xxxxxxxxxxxx | SPM402G-P500xxxxxxxxxxxx |
SPM402G-P005xxxxxxxxxxxx Performance Characteristics
ClosePARAMETER | MIN | NOM | MAX | UNITS | Notes |
Standard Pressure Ranges | - | - | - | - | - |
Output Signal (Offset) | - | - 2 mV | 0 mV | 2 mV | - |
Output Signal (Span) | - | 50 mV | 75 mV | 100 mV | - |
Supply/Performance Characteristics | - | - | - | - | - |
Supply current (mA) | - | - | 1 mA | 3 mA | - |
Supply voltage (V) | - | - | - | 10 V | - |
Linearity [%FS0 BFSL] | - | - 0.25 | ± 0.1 | 0.25 | - |
Hysteresis [%FSO] | - | - 0.05 | ± 0.03 | 0.05 | - |
Input impedance [kΩ] | 4.0 to 6.0 | - | - | - | - |
Output impedance [kΩ] | 4.0 to 6.0 | - | - | - | - |
Insulation resistance [MΩ] | 50 (between housing and sensor chip) A@ 50 VDC | - | - | - | - |
Standard Pressure Range
Operating Range
0 - 5 PSI
Proof Pressure
30 PSI
Negative Pressure
-
Burst Pressure
45 PSI