TLAX Series
-
Features
- 0.5 to 30 inH2O and 1 to 150 PSI Pressure Ranges
- 4-20mA, 2-Wire Current Loop Output
- Temperature Ranges: 0° to 50°C
- Calibrated Zero, Span and Thermal Effect
- 12 to 32 VDC
- Reverse Polarity Protection
-
Applications
- HVAC
- Industrial Controls
- Environmental Controls
- Air Sampling Equipment
equivalent Circuit

Pressure Sensor Maximum Ratings
Environmental Specification
Available Package
Click On Package Image Below To View Package Drawing
Help Me Choose
Choose A Part Number Below To View Performance Characteristics
Pressure Range | Differential | Absolute | Gauge |
0.5 inH2O | TLAX-F50D | -- | -- |
1 inH2O | TLAX-L01D | -- | TLAX-L01G |
2 inH2O | TLAX-L02D | -- | TLAX-L02G |
4 inH2O | TLAX-L04D | -- | TLAX-L04G |
5 inH2O | TLAX-L05D | -- | TLAX-L05G |
10 inH2O | TLAX-L10D | -- | TLAX-L10G |
20 inH2O | TLAX-L20D | -- | TLAX-L20G |
1 PSI | TLAX-001D | -- | TLAX-001G |
30 inH2O | TLAX-L30D | -- | TLAX-L30G |
5 PSI | TLAX-005D | -- | TLAX-005G |
15 PSI | TLAX-015D | -- | TLAX-015G |
30 PSI | TLAX-030D | -- | TLAX-030G |
60 PSI | TLAX-060D | -- | TLAX-060G |
100 PSI | -- | -- | TLAX-100G |
150 PSI | -- | -- | TLAX-150G |
TLAX-150G Performance Characteristics
ClosePARAMETER | MIN | NOM | MAX | UNITS | Notes |
Full Scale Span (FSS) | - | 16 | - | mA | 1 |
Full Scale Output | - | 20 | - | mA | 1 |
Offset | - | 4 | - | mA | 1 |
Accuracy | - | ±0.5 | - | %FSS | 2 |
Total Error Band (TEB) - @ 25°C | - | - | ±1.0 | %FSS | 3 |
Total Error Band (TEB) - 0°C to 50°C | - | - | ±2.0 | %FSS | 3 |
Offset Long Term Drift (1 year) | - | ±1.0 | - | %FSS | - |
Current Consumption | - | - | 22 | mA | - |
Reverse Polarity Protection | - | YES | - | - | - |
Response Time (0-100% FSO) | - | 10 | - | sec | - |
Standard Pressure Range
Operating Range
0 to 150 PSI (1034 kPa)
Proof Pressure
200 PSI (1379 kPa)
Burst Pressure
250 PSI (1724 kPa)
Specification notes
NOTE 1: Performance Parameters are measured with 24VDC and RLOAD of 250Ω.
NOTE 2: Accuracy includes linearity (BFSL), hysteresis & repeatability at 25°C
NOTE 3: Total accuracy is the combined error from offset and span calibration, non-linearity, pressure hysteresis, and temperature effects. Calibration errors include the deviation of offset and full scale from nominal values.