DLHR Series
-
Features
- 0.5 to 60 inH2O
- 1.68V to 3.6V Supply Voltage
- I2C or SPI Interface (Automatically Selected)
- High Resolution 16/17/18 Bit Output
- Better than 0.25% Accuracy Over Temperature Typical
-
Applications
- Medical Breathing
- Enviromental Controls
- HVAC
- Industrial Controls
- Portable/Hand-Held Equipment
equivalent Circuit

Pressure Sensor Maximum Ratings
Environmental Specification
Help Me Choose
Choose A Part Number Below To View Performance Characteristics
DLHR-L10D Performance Characteristics
ClosePARAMETER | MIN | NOM | MAX | UNITS | Notes |
Output Span (FSS) | - | ±0.4 * 2 24 | - | Dec count | 1 |
Offset Output @ Zero Diff. Pressure (OSdig) | - | 0.5 * 2 24 | - | Dec count | - |
Total Error Band | - | 0.5 | 1.0 | %FSS | 2 |
Span Temperature Shift | - | ±0.2 | - | %FSS | 3 |
Offset Temperature Shift | - | ±0.2 | - | %FSS | 3 |
Offset Warm-up Shift | - | ±0.15 | - | %FSS | 4 |
Offset Position Sensitivity (±1g) | - | ±0.05 | - | %FSS | - |
Offset Long Term Drift (One Year) | - | ±0.15 | - | %FSS | - |
Linearity, Hysteresis Error | - | ±0.25 | - | %FSS | 6 |
Pressure Digital Resolution - No Missing Codes | - | - | - | - | - |
16-bit Option | 15.7 | - | - | bit | - |
17-bit Option | 16.7 | - | - | bit | - |
18-bit Option | 17.7 | - | - | bit | - |
Temperature Output | - | - | - | - | - |
Resolution | - | 16 | - | bit | - |
Overall Accuracy | - | 2 | - | °C | - |
Supply Current Requirement | - | - | - | - | 5, 7, 8 |
During Active State (ICCActive) | - | 2.0 | 2.6 | mA | - |
During Active State (ICCIdle) | - | 100 | 250 | mA | - |
Power on Delay | - | - | 2.5 | ms | 5 |
Data Update Time (tDU) | - | (see table below) | - | ms | 5, 7 |
Standard Pressure Range
Operating Range
±10 inH2O
Proof Pressure
200 inH2O
Burst Pressure
300 inH2O
Nominal Span
±0.4 * 224