DLV Series
-
Features
- 5 to 60 PSI and Barometric Pressure Ranges
- 3.3V or 5.0V Supply Voltage
- I2C or SPI Interface
- High Resolution 14 Bit Output
- Better than 0.5% Accuracy Over Temperature Typical
-
Applications
- Medical Breathing
- Enviromental Controls
- HVAC
- Industrial Controls
- Portable/Hand-Held Equipment
equivalent Circuit

Pressure Sensor Maximum Ratings
Environmental Specification
DLV-005D Performance Characteristics
ClosePARAMETER | MIN | NOM | MAX | UNITS | Notes |
Output Span | - | ±6,553 | - | Dec count | 1 |
Offset Output | - | 8,192 | - | Dec count | - |
Total Error Band | - | ±0.5 | ±1.0 | %FSS | 2 |
Span Temperature Shift | - | ±0.1 | - | %FSS | 3 |
Offset Temperature Shift | - | ±0.1 | - | %FSS | 3 |
Offset Warm-up Shift | - | ±0.1 | - | %FSS | 4 |
Offset Long Term Drift (One Year) | - | ±0.1 | - | %FSS | - |
Linearity, Hysteresis Error | - | ±0.1 | ±0.25 | %FSS | 6 |
Response Delay | - | - | - | - | 5,10 |
Sleep-Wake Pressure | - | 0.40 | 0.50 | ms | 5 |
Sleep-Wake All | - | 1.10 | 1.40 | ms | 5 |
Power-On to First Reading Attempt | 6.0 + 1 update period | - | - | ms | - |
Update Rate | - | - | - | - | - |
Fast | - | 0.40 | 1.0 | ms | 5 |
Noise Reduced | - | 1.30 | 3.1 | ms | 5 |
Low Power | - | 6.5 | 9.5 | ms | 5 |
Start-up Time | - | - | 10.0 | ms | 5,7 |
Digital Resolution | - | - | - | - | - |
Output Resolution | - | 14 | - | bit | 5 |
No Missing Codes | 12 | 13 | - | bit | 5 |
Temperature Output | - | - | - | - | - |
Resolution | - | 11 | - | bit | 8 |
Overall Accuracy | - | 2 | - | °C | 8 |
Current Requirement (3.3V Option) | - | - | - | - | - |
Fast | - | 2.5 | 3.2 | mA | 5 |
Noise Reduced | - | 2.5 | 3.1 | mA | 5 |
Low Power | - | 0.6 | 0.7 | mA | 5 |
Sleep (Idle) | - | 0.5 | 5.0 | uA | 5 |
Current Requirement (5.0V Option) | - | - | - | - | - |
Fast | - | 3.5 | 4.5 | mA | 5 |
Noise Reduced | - | 3.6 | 4.4 | mA | 5 |
Low Power | - | 0.8 | 1.0 | mA | 5 |
Sleep (Idle) | - | 0.5 | 5.0 | uA | 5 |
Standard Pressure Range
Operating Range
±5 PSI
Proof Pressure
20 PSI
Burst Pressure
40 PSI
Nominal Span
±6,553 counts
Specification notes
NOTE 1: The span is the algebraic difference between full scale decimal counts and the offset decimal counts.
Pressure Output Transfer Function:
Where,
Poutdig Is the sensor 14 bit digital output
OSdig Is the specified digital offset (gage and absolute = 1,638)
FSS (psi) Is the sensor Full Scale Span in psi
NOTE 2: Total error band comprises of offset and span temperature and calibration errors, linearity and pressure hysteresis errors, offset warm-up shift, offset position sensitivity and long term offset drift errors.
NOTE 3: Shift is relative to 25°C.
NOTE 4: Shift is within the first hour of excitation applied to the device.
NOTE 5: Parameter is characterized and not 100% tested.
NOTE 6: Measured at one-half full scale rated pressure using best straight line curve fit.
NOTE 7: Power-on time is time from power being applied to first available part communications.
NOTE 8: Temperature output conversion function:
Temperature Output Transfer Function: